H.I.Fraser is the Australian representative for Teamtec Fire Rated windows. TeamTec fire rated windows are available in fire class A-0, A-60 and H-120. They withstand fire, water pressure and explosions, and give a satisfactory range of sound reduction values. A description of TeamTec's window is as follows:
|
Fire class |
A-0 window |
A-60 window |
A-60 side scuttle |
H-120 window |
|
Max clear opening [mm] |
1600 x 1300 |
2000 x 1600 |
Diameter 350/450 |
1000 x 1000 |
|
Total thickness glass [mm] |
Min. 26 mm |
Min. 47 mm |
Min. 47 mm |
Min. 101 mm |
|
Steel bulkhead cut out relative to clear opening [mm] |
158 |
164 |
106 |
164 |
|
Optical quality: |
IMO STCW-95 |
|||
|
Light transmittance |
90 % |
Approx. 78% |
Approx. 78% |
Approx. 78% |
|
Solar energy transmittance |
Approx. 82% |
< 67% |
< 67% |
< 59% |
|
UV-light transmittance |
Approx. 53% |
Negligible |
Negligible |
Negligible |
|
Refraction |
Negligible |
Negligible |
Negligible |
Negligible |
|
Flatness |
ISO 3934 |
ISO 3934 |
ISO 3934 |
ISO 3934 |
|
U-value [W/m²K] |
1.1-2.9 |
1.1-2.7 |
1.1-2.7 |
1.1-2.7 |
|
Tested mechanical strength [bar] |
Min. 2.5 bar for A60 600x450 mm with 8 mm toughened glass |
|||
|
Fire tested according to IMO 754(18) |
x |
x |
x |
x |
|
Hose stream tested |
|
x |
|
|
|
Heat radiation tested |
|
x |
x |
x |
|
Blast resistance [bar] |
Calculations |
Calculations |
|
Calculations |
|
Sound reduction [dB] |
35-53 |
48-64 |
>48 |
48-64 |
|
Options: |
|
|||
|
Tinted glass |
x |
x |
x |
x |
|
Venetian blinds |
x |
x |
|
x |
|
Roller blinds |
x |
x |
|
x |
|
Stainless steel frame |
x |
x |
x |
x |
|
Bullet proofing* |
x |
x |
x |
x |
|
Deadlight |
|
|
x |
|